Wire-Pak™ electrical wiring
system was introduced in 1984. Wire-Pak™ is a custom designed,
modular wiring system that literally snaps together as the
building is assembled. The male and female connectors used are
directional; thus ensuring the system cannot be assembled
incorrectly -- there's no guess work.
All Wire-Pak™ pieces are
interchangeable allowing for last minute field alterations. The
exception to this are our 3-way switches which must be assembled
in accordance to the layout provided.
Note: 3-way switches use
circuits C/2 and C/3, no other item can be on C/3 with a 3-way
switch.
This comes all pre wired.
Wire-Pak™ Specifications:
- 6 wire system utilizing three separate circuits for 110
volts 20 amps only
- Circuit 1 (C/1) typically for outlets uses Red - Hot,
White - Neutral, Green - Ground
- Circuit 2 (C/2) typically for Lights uses Black - Hot,
White - Neutral, Green - Ground
- Circuit 3 (C/3) typically for 110v air conditioners or
isolated lines uses Blue - Hot, Gray - Neutral, Green -
ground
- All wiring is 12 gage, THHN type, Stranded copper
- All conduit to be 1/2" flexible type, .638 inside
diameter, .91 outside diameter
- The system conforms to the National Electric Code
- All Components are UL Listed and Recognized (UL File no.
E86583)
- 220 volt outlets may be provided as separate runs to the
breaker box
- Conduit clips are provided for fastening the cabling and
junction boxes to the roof. Flex conduit should be fastened
every 4-1/2' and within 12" of every junction box or fitting
- All cable runs shall not exceed 12' without having a
junction box connector
- An electrician will only be required to bring power to
the building and complete the hook-up at the breaker panel.
- No other field wiring will be necessary.
- A complete bill of materials and electrical schematic
are provided.
Wire-Pak™ Features:
- Competitive with conventional wiring.
- 100% reusable
- Easy to install with a "fool proof" design
- Future outlets can be added as needs require
- UL listed Components
- Meets NEC requirements
- Accepted by most building codes across the USA.
| |
| |
| |
| |
B-n
|
Flex jumper between outlets, lights, etc.
(always female)
|
| |
C888
|
Universal connector junction box
(always male)
|
| |
G-n
|
Outlet assembly
(always female) |
| |
F-n
|
Switch assembly
(always female) |
| |
H-n
|
220 volt direct wire
outlet assembly
(always pig tail) |
| |
Warnings:
Risk of fire or electrical shock. Do not electrically
connect any panel or assembly to more than one supply source.
Always determine that each panel or assembly is connected to one
and only one electrical power source. Note: The only known areas
where this product is not acceptable by code is Cook County,
Illinois. Los Angeles County, California requires county
approval for all electrical systems, the expense does not
justify having this. It is the responsibility of the purchaser
to check for any local code restrictions.
Back
Modular-Office.com is a reseller for National
Partitions.